ՌԵՏԻՆԱՄԵՏԱՂԵ ՍԵՅՍՄԱՄԵԿՈՒՍԻՉ ՀԵՆԱՐԱՆՆԵՐՈՎ ԵՐԿԱԹԲԵՏՈՆԵ ՇՐՋԱՆԱԿԱԿԱՊԱՅԻՆ ՀԱՄԱԿԱՐԳԵՐՈՎ ՇԵՆՔԵՐԻ ՏՆՏԵՍԱՊԵՍ ՇԱՀԱՎԵՏՈՒԹՅԱՆ ՄԱՍԻՆ

ՍԵՅՍՄԱԿԱՅՈՒՆ ՇԻՆԱՐԱՐՈՒԹՅՈՒՆ

  • Տ. Լ. Դադայան ՃՇՀԱՀ
  • Խ. Գ. Վարդանյան ՃՇՀԱՀ
Keywords: seismic isolation, seismic action, reinforce concrete, multi-story building

Abstract

One of the main objectives of earthquake engineering around the world is the ensuring of the bearing capacity of buildings and the safety of people during a seismic action with a possible decrease of construction expenses. Various types of seismic isolation systems have been spread in recent decades. The estimation of economic efficiency of isolation systems is shown in the article based on the example of various multi-story reinforced concrete frame-wall buildings with seismic isolators used in RA and without them. At the same time consumption of the materials of a bearing system were defined by applicable building codes is used as a parameter of efficiency.

Author Biographies

Տ. Լ. Դադայան, ՃՇՀԱՀ

Դադայան Տիգրան Լեոնիդի , տ.գ.դ. , դոցենտ (ՀՀ, ք. Երևան) - ՃՇՀԱՀ, Շինարարական կոնստրուկցիաներ ամբիոնի վարիչ , (+374) 0 93 5 4391 1

Խ. Գ. Վարդանյան, ՃՇՀԱՀ

Վ ա ր դ ա ն յ ա ն  Խ ա չ ա տ ո ւ ր  Գ ր ի գ ո ր ի( Հ Հ , ք . Ե ր և ա ն ) – ՃՇՀԱՀ , Շինարարական կոնտրուկցիաների ամբիոն, դասախոս, xavar@mail.ru

Published
2015-12-03
Section
Статьи